Nuclear Medicine AtlasInteractive atlas

GFR Measurement⁹⁹ᵐTc-DTPA (or ⁵¹Cr-EDTA)

Camera-based (Gates) and plasma-clearance methods for glomerular filtration rate

Evidence B#genitourinary#renal#GFR#functionUpdated 2026-07-27 · Physician-reviewed
High-yield mode — key points, high-yield facts, tables & quizzes only. Toggle off for full text.

Quick Answer

Radionuclide GFR provides a measured (not estimated) glomerular filtration rate using a purely filtered tracer — Tc-99m-DTPA or Cr-51-EDTA. Two approaches: the camera-based Gates method derives GFR from the fraction of injected activity taken up by the kidneys over the first few minutes (with depth/attenuation correction), while plasma-sampling clearance measures the tracer's disappearance from blood over time. Measured GFR is used where accuracy matters — chemotherapy dosing, potential kidney donors, and discordant eGFR.

Methods

  • Gates (camera) method: GFR from renal uptake as a percentage of injected dose, corrected for renal depth (from height/weight) and background; also yields split GFR by combining with differential function.
  • Plasma clearance: single- or multiple-sample blood measurements after a filtered-tracer bolus; considered the more accurate radionuclide method.

When measured GFR is preferred

  • Cytotoxic/chemotherapy dosing (e.g. carboplatin) requiring an accurate absolute GFR.
  • Potential living kidney donors (absolute and split function).
  • Discrepant or unreliable creatinine-based eGFR (extremes of body habitus, amputees, unstable function).

Measured, not estimated — and split matters

Radionuclide GFR gives a measured (not creatinine-estimated) filtration rate using a purely filtered tracer (Tc-99m-DTPA or Cr-51-EDTA, not the tubular agent MAG3). Plasma-sampling clearance is the more accurate method; the camera-based Gates method is faster and additionally yields split GFR (= total measured GFR × differential function) — the actionable number before nephrectomy or living kidney donation. Reach for measured GFR when accuracy matters: carboplatin/chemo dosing, donor evaluation, or discordant eGFR.

High-Yield Pearls

  • Split GFR = measured total GFR × differential function — the actionable number before nephrectomy/donation.
  • Plasma-sampling clearance is generally more accurate than camera Gates; Gates is faster and gives split function.
  • Uses a filtered tracer (DTPA/EDTA), not the tubular agent MAG3.

Common Pitfalls

  • Depth/attenuation-correction errors in the Gates method (body habitus).
  • Extravasated injection invalidating the injected-dose reference.
  • Tracer: Tc-99m-DTPA / Cr-51-EDTA (filtered); contrast: MAG3 (tubular, for renography).

Self-Check

Q1. Why must GFR use a filtered tracer (DTPA/EDTA) rather than MAG3?

Answer: GFR requires a purely glomerular-filtered tracer; MAG3 is tubularly secreted, so it measures effective renal plasma flow, not filtration.

Q2. Which radionuclide GFR method is generally more accurate, and which additionally yields split GFR?

Answer: Plasma-sampling clearance is more accurate; the camera-based Gates method is faster and gives split GFR.

Q3. Give two clinical situations where measured (not estimated) GFR is preferred.

Answer: Carboplatin/chemotherapy dosing and living kidney-donor evaluation (also discordant/unreliable creatinine-based eGFR).

Q4. How is split GFR calculated and why does it matter before nephrectomy?

Answer: Split GFR = total measured GFR × differential function — the actionable per-kidney number before nephrectomy or donation.

Evidence & sources

BSNMMI/EANM / BNMS GFR guidelines — Gates camera method and plasma-clearance measurement of GFR (Tc-99m-DTPA / Cr-51-EDTA).
Cite this page. Nuclear Medicine Atlas. “GFR Measurement.” v1.76, 2026-10-25. Permalink: https://nuc.med/gfr-measurement/ Report an issue